• HEAT IS CAPTURED UNDER THE FORM OF SOLAR RADITION, ENVIRONMENTAL TEMPERATURE, RAIN, WIND AND EVEN SNOW
  • THE HEAT PRODUCED ON COLDER DAYS, EVEN AT NIGHT IS SUFFICIENT TO ATTAIN THE WATER TEMPERATURE DESIRED
  • THE SOLAR PANEL IS LIGHT, DISCREET AND VERSATILE IN TERMS OF WHERE TO PUT IT
  • OUTSIDE CYLINDER CONDENSER (NO CONTACT WITH WATER)
  • 3RD GENERATION THERMODYNAMIC SOLAR ENERGY
  • HOT WATER UP TO 55ºC AVAILABLE 24h PER DAY
  • ALMOST NON-EXISTENT MAINTENANCE
  • THE ENERGY CONSUMPTION OF THE EQUIPMENT IS REDUCED DUE TO A SUPER EFFICIENT COMPRESSOR
  • NO DEFROST CYCLE

Autonomous Hot Water solution available in version with 1 thermodynamic solar panel


Eco offers a wide range designed for professionals from this industry, with various capacities, available in models of 200 to 450 litres. Version of 1 or 2 thermodynamic solar panel and thermal storage equipped with or without supplementary coil.


 

 

 
STORAGE WATER HEATER 200i 250i 300i 200ix 250ix 300ix
Net Weight Kg. 58 65 71 61 68 74
Volume L 200 250 300 195 245 295
Water Heater - Stainless Steel
Cathodic Protection - Mg Anode (1”1/4)
Hydraulic Connections Water - Inlet and Outlet Pol. 3/4” 3/4” 3/4” 3/4” 3/4” 3/4”
PT Valve 1/2” 1/2” 1/2” 1/2” 1/2” 1/2”
Recirculation 3/4” 3/4” 3/4” 3/4” 3/4” 3/4”
Coil | Entrance and Exit - - - 1" 1" 1"
Insulation - High density polyurethane 50mm
Maximum Pressure Bar 7 7 7 7 7 7
Maximum Temperature 0C 80 80 80 80 80 80
Heat Loss (EN12897) kWh/24h 0.99 1.01 1.17 0.99 1.01 1.17
 
THERMODYNAMIC SOLAR PANEL
Material - Anodized Aluminum Solarcoat
Dimensions (W x H x D) mm 2000 x 800 x 20
Weight Kg. 8
 
THERMODYNAMIC BLOCK
Absorbed Power (Avg/Max) W 350 | 600
Thermal Power (Avg/Max) W 1250 | 2100
Electric Support Power W 1500
Refrigerant Fluid / Qt.1 -/g R134a / 1100
Piping Material - Copper (DHP ISO1337)
Liquid line | Asp. Pol. 1/4” | 3/8”
Power Supply V / Hz 220-240 / Single-phase / 50 ou 602
Fuse (General | Resistance) A 10 | 10
Operating Temperatures 0C -5 | 45
 
PERFORMANCE4 250i 250i 300i 200ix 250ix 300ix
Load Profile - L XL XL L XL XL
Coefficient of Performance (COP) - 3.6 3.8 3.7 3.6 3.8 3.7
Energy Efficiency Class - A++ A+ A+ A++ A+ A+
Energy Efficiency - 154 155 151 154 155 151
Annual Energy Consumption KWh/year 664 1078 1111 664 1078 1111
Amount of useful water at 400C L 247 349 389 240 342 382
Temperatura de Fábrica 0C 53 53 53 53 53 53
Interior Sound Level dB            
 
1The amount of fluid must be verified by the installer. In certain cases, it is necessary to adjust the amount of fluid to guarantee the correct functioning of the system.
2The 60 Hz frequency is only available upon order.
3 According to EN16147, Delegated Regulation (EU) Nº812/2013 and Delegated Regulation (EU) Nº814/2013.
DIMENSIONS mm 250I 250I 300I 200IX 300ESM 300IX
A 99 99 107 99 99 107
B - - - 215 215 236
C - - - 706 706 636
D 820 840 787 820 840 787
E 940 1025 1096 940 1025 1096
F 1044 1343 1187 1044 1343 1187
G 1180 1475 1330 1180 1475 1330
H 580 580 650 580 580 650
I 1615 1915 1775 1615 1915 1775
M 800
N 2000
O 20
 
  • 1DHW Cylinder
  • 2Condenser
  • 3Optional Supplementary Coil
  • 4Ceramic Resistance + Thermostat + Temperature Sensor
  • 5Magnesium Anode
  • 6High Density Insulation
  • 7Outside Coating
  • 8Thermodynamic Block
  • 9Cover
  • 10ElectronicController

Version with 1 Thermodynamic Solar Panel stainless steel cylinder With or without Supplementary Coil.



THERMODYNAMIC
SOLAR PANEL



  • ANODIZED ALUMINIUM, WITH FLEXIBLE COATING
  • LIGHT WEIGHT – ONLY 8 KILOS, EASY TO TRANSPORT AND INSTALL
  • DIMENSIONS: 2m X 0,8m X 0,02m
  • NO GLASS, RUBBER OR FRAGILE MATERIALS
  • NO RISK OF OVER HEATING
  • NO RISK OF FREEZING
  • HIGH RESISTANCE IN SALINE ENVIRONMENT
  • HIGH RESISTANCE TO HUMIDITY
  • IT CAN BE INSTALLED FROM 10º TO 85º IN A HORIZONTAL POSITION
  • IT CAN BE INSTALLED ON THE ROOF, WALL, IN THE GARDEN, ETC...
  • THE PANEL DOES NOT LOSE ITS EFFICIENCY WITH TIME OR WITH DIRT
  • NO NEED TO CLEAN
  • ESTIMATED USEFUL LIFE OF 25 YEARS

 

THERMODYNAMIC SOLAR SYSTEM
OPERATING PRINCIPLE


EQUIPMENT

> Without ducts
> Without ventilators
> Without defrost cycles that use up energy
> Super efficient compressor with low energy consumption
> No need to install support equipment
> Hot water guaranteed, available day and night, hail, rain, wind or shine up to 55ºC

SOLAR PANEL

> Captures heat regardless of climate.
> Primary circuit does not need to dissipate excess heat on hotter days.
> Easy integration with architecture, versatile, no visual impact.

 

 

The Thermodynamics Solar System joins two incomplete technologies, the heat pump and the solar thermal collector.
Heat pumps are quite efficient equipment but the heat they produce from their renewable component varies only according to changes in the temperature of the environment.
Thermal solar collectors are the best source of heat on hot and sunny days but they are totally inefficient whenever there is no sun.
The Thermodynamic Solar Technology manages to surpass the limitations of both the heat pump and solar collector technologies.
Through the cooling liquid (R134a or R407c) which covers a closed circuit, the liquid goes into the solar panel and suffers the action of sun, rain, wind, environment temperature and other climate factors. During this process the liquid gains heat in a more favourable way than a heat pump. After this stage, the heat is transferred to an exchanger with the help of a small compressor, which heats the water. The liquid cools down and the circuit is repeated.
As the fluid has a boiling temperature.
Of approximately -30ºC, the system works even when there is no sun and it even works at night, providing hot water at 55ºC, day and night, hail, rain, wind or shine, unlike the traditional solar thermal system.
The energy consumption of the system is basically the same as a fridge compressor that makes the liquid circulate. There are no ventilators that help the evaporation process, or defrost cycles, which imply unnecessary energy consumption, unlike what happens with heat pumps.
 
  • 1LCD colour screen
  • 2ON / OFF General
  • 3ON / OFF Compressor
  • 4ON / OFF Anti-legionella
  • 5Menu
  • 6Electrical support (malfunction)
  • 7Execute | Lock / Unlock

 

 

ECO Operating Mode
In the ECO operating mode, the equipment only works as a Thermodynamic Solar System to heat water in the thermal storage. Thus we can have higher efficiency, guaranteeing maximum saving for the user.
AUTO Operating Mode
In the AUTO operating mode, the equipment works as a Thermodynamic Solar System and/or electrical support, there being an automatic management between the operating of the solar system and electrical support, in order to maintain the efficiency of the equipment, thus providing a higher quantity of hot water available.
BOOST Operating mode
In the BOOST operating mode the equipment works with a Thermodynamic Solar System and electrical support simultaneously. This mode allows the user to get hot water in a shorter amount of time


Company, Products, Associates, Co-Funded Project