This content is restricted to professionals.
Register to access this exclusive content.
If you already have your access data, log in
Aerothermal heat pump, designed for heating water for domestic or industrial use.
Hot water up to 60°C, with maximum efficiency.
The Aquapura Split Heat Pump is available in capacities of 160 liters, wall mounted version, and 250 liters to 500 liters.
It consists of an indoor unit, the water heater, and the outdoor unit, the Split heat pump.
There is a cooling liquid that is pumped to an outdoor heat exchanger (evaporator). Here the liquid, with the help of a fan, absorbs the energy from the atmosphere to the temperature differential obtained outdoors. During this process, the liquid changes to a gaseous state. The gaseous state is sucked in by the mechanical part of the system, the compressor. Here it is compressed, the pressure goes up and consequently the liquid temperature increases. After this, the liquid travels to a second inside heat exchanger (condenser) and transfers heat to the water in the cylinder. The fluid goes into liquid state by cooling down. The liquid pressure is reduced due to a strangulation that happens in the expansion valve and the process starts again.
We select the best components and subject our systems to rigorous quality testing to ensure maximum customer satisfaction.
The AQUAPURA SPLIT heat pump is a modern, efficient, and clean solution that guarantees comfort in your home, while always respecting the environment. It is a smart way to use natural resources to improve your quality of life; by adopting this solution you will be making a serious commitment to the issue of reducing harmful emissions into our atmosphere, therefore contributing to the natural balance of the planet. It is a solution that adapts to both domestic and industrial use, i.e. for hot water consumption in facilities such as: Hotels Guest houses, Hospitals, Gyms, Etc. The heat pump for AQUAPURA SPLIT is direct-contact condenser technology. It has two parts: Split-system heat pump which is installed outdoors, DHW heater installed indoor. The interconnection between the two parts is done with refrigerating connections (up to 20 meters). The AQUAPURA SPLIT can be used at outdoor temperaturesof up to -150C, allowing for the production of domestic hot water up to 650C just with the compressor, which allows fordirect replacement of the existing electric cylinder or water heater.
The electronic controller that is part of the AQUAPURA SPLIT heat pump is a simple and intuitive programmer that allows for:
OUTSIDE UNIT | SPLIT 160 | 250 | 300 | 500 | ||||
---|---|---|---|---|---|
Weight | Kg. | 33 | |||
Refrigerating connections | pol. | 1/4” | 3/8” | |||
Sound level | dB | 59 | |||
Power supply | V/Hz | 230/50 | |||
Protection Index | - | 600/1000 | |||
Absorbed electrical power (HP) (med / max) | W | 600/1000 | |||
Thermal power supplied (HP) (med / max) | W | 1920/3200 | |||
Maximum distance between units | m | 20 (hight max. 10) | |||
Outdoor operating temperature range | °C | -14 / 43 | |||
Refrigerating fluid | tipo/g | R134a / 1600 | |||
Air flow | m3/h | 1300 | |||
DIMENSIONS mm | |||||
A | 804 | ||||
B | 555 | ||||
C | 302 | ||||
D | 452 | ||||
E | 137 |
CYLINDER TECHNICAL DATA | SPLIT 160 (MURAL) | ||||
---|---|---|---|---|---|
Capacity | L | 160 | |||
Dimensions (ø | height) | mm | 530/1141 | |||
Gross weight | Kg. | 32 | |||
Material | - | Stainless Steel Duplex 2205 | |||
Insulation | - | High density polyurethane (55mm) | |||
Maximum water temperature | °C | 80 | |||
Maximum operation pressure | bar | 7 | |||
Thermal loss (1) | kWh/24h | 0,94 | |||
Protection Index | - | IPX1 | |||
Auxiliary coil power | W | 1500 | |||
Refrigerating connections | pol. | 1/4” | 3/8” | |||
(1) According to EN12897 | |||||
PERFORMANCE | |||||
Tapping profile | - | L | |||
COP 2 | - | 3,75 | |||
COP 3 | - | 3,26 | |||
Amount of water removed at 40°C | L | 194 | |||
Energy efficiency class | - | A+ | |||
Energetic efficiency | % | 135 | |||
Annual electricity consumption | kWh/year | 759 | |||
(2) A14/t35, EN16147 (3) EN16147: EN16147: Water heating from 10°C to 54°C (air temperature 14°C) |
|||||
DIMENSIONS mm | SPLIT 160 (MURAL) | ||||
A | 1141 | ||||
BØ | 530 | ||||
C | 550 | ||||
D | 750 | ||||
E | 235 | ||||
F | 275 | ||||
G | 220 |
CYLINDER TECHNICAL DATA | SPLIT 250 I/IX | SPLIT 300 I/IX | SPLIT 500 I/IX | ||
---|---|---|---|---|---|
Capacity | L | 250 / 245 | 300 / 295 | 455 / 445 | |
Dimensions (ø | height) | mm | 580 / 1540 | 650 / 1400 | 650 / 2020 | |
Gross weight | Kg. | 46 / 51 | 50 / 55 | 73 / 95 | |
Material | - | Stainless Steel AISI444 | |||
Insulation | - | High density polyurethane (55mm) | |||
Corrosion protection | - | Magnesium anode 1” 1/4 (if applicable) | |||
Maximum water temperature | °C | 80 | |||
Maximum operation pressure | bar | 7 | |||
Thermal loss (1) | kWh/24h | 1,01 | 1,17 | 1,81 | |
Coil (ø | length) | m | 0,025 | 10 | 0,025 | 10 | 0,025 | 24 | |
Coil thermal power (2) | kW | 20 | 20 | 54 |
|
Protection Index | - | IPX1 | |||
Auxiliary coil power | W | 1500 | 1500 | 2200 | |
Refrigerating connections | pol. | 1/4” | 3/8” | 1/4” | 3/8” | 1/4” | 3/8” | |
(1) According to EN12897 (2) Primary circuit (Te=90°C; Ts=80°C); DHW circuit (Te=10°C; Ts=60°C) |
|||||
PERFORMANCE | |||||
Tapping profile | - | XL | XL | XXL | |
COP 3 | - | 3,4 | 3,4 | 3,5 | |
Amount of water removed at 40°C | L | 323 | 362 | 599 | |
Energy efficiency class | - | A+ | A+ | A+ | |
Energetic efficiency | % | 139 | 143 | 139 | |
Annual electricity consumption | kWh/ano | 1203 | 1170 | 1549 | |
(3) EN16147: Water heating from 10°C to 54°C (air temperature 14°C) | |||||
DIMENSIONS mm | SPLIT 250 I/IX | SPLIT 300 I/IX | SPLIT 500 I/IX | ||
A | 99 | 107 | 102 | ||
B | 215 | 236 | 635 | ||
C | 706 | 636 | 1525 | ||
D | 840 | 787 | 782 | ||
E | 1025 | 1096 | 1093 | ||
F | 1343 | 1187 | 1770 | ||
G | 1475 | 1330 | 1937 | ||
H | 1540 | 1400 | 2020 | ||
I | Ø 580 | Ø 650 | Ø 650 | ||
J | 688 | 758 | 758 |