energie

Register to access this exclusive content. If you already have your access data, log in

Aquapura Split

homepage / Products / Aquapura Split

Aerothermal heat pump, designed for heating water for domestic or industrial use.

Hot water up to 60°C, with maximum efficiency.

The Aquapura Split Heat Pump is available in capacities of 160 liters, wall mounted version, and 250 liters to 500 liters.
It consists of an indoor unit, the water heater, and the outdoor unit, the Split heat pump.

EFFICIENCY & QUALITY

OPERATING PRINCIPLE

There is a cooling liquid that is pumped to an outdoor heat exchanger (evaporator). Here the liquid, with the help of a fan, absorbs the energy from the atmosphere to the temperature differential obtained outdoors. During this process, the liquid changes to a gaseous state. The gaseous state is sucked in by the mechanical part of the system, the compressor. Here it is compressed, the pressure goes up and consequently the liquid temperature increases. After this, the liquid travels to a second inside heat exchanger (condenser) and transfers heat to the water in the cylinder. The fluid goes into liquid state by cooling down. The liquid pressure is reduced due to a strangulation that happens in the expansion valve and the process starts again.

  1. Storage Water Heater
  2. Condenser (Coil)
  3. Ceramic Resistance + Thermostat + Sensor
  4. Magnesium Anode (if applicable)
  5. High Density Insulation
  6. Split Cover
  7. Electronic Controller
  8. Fan
  9. Evaporator
  10. Expansion Valve
  11. Unit box
  12. Compressor

DOMESTIC HOT WATER HEAT PUMP

We select the best components and subject our systems to rigorous quality testing to ensure maximum customer satisfaction.

AQUAPURA SPLIT

The AQUAPURA SPLIT heat pump is a modern, efficient, and clean solution that guarantees comfort in your home, while always respecting the environment. It is a smart way to use natural resources to improve your quality of life; by adopting this solution you will be making a serious commitment to the issue of reducing harmful emissions into our atmosphere, therefore contributing to the natural balance of the planet. It is a solution that adapts to both domestic and industrial use, i.e. for hot water consumption in facilities such as: Hotels Guest houses, Hospitals, Gyms, Etc. The heat pump for AQUAPURA SPLIT is direct-contact condenser technology. It has two parts: Split-system heat pump which is installed outdoors, DHW heater installed indoor. The interconnection between the two parts is done with refrigerating connections (up to 20 meters). The AQUAPURA SPLIT can be used at outdoor temperaturesof up to -150C, allowing for the production of domestic hot water up to 650C just with the compressor, which allows fordirect replacement of the existing electric cylinder or water heater.

HIGH LEVELOF EFFICIENCY

DOMESTIC HOT WATER PRODUCTION

The electronic controller that is part of the AQUAPURA SPLIT heat pump is a simple and intuitive programmer that allows for:  

  • The adjustment of the heat pump temperature set point
  • The adjustment of the auxiliary coil temperature set point
  • Time programming
  • The setting of parameters and temperatures

 

OUTSIDE UNITSPLIT 160 | 250 | 300 | 500
WeightKg.33
Refrigerating connectionspol.1/4” | 3/8”
Sound leveldB59
Power supplyV/Hz230/50
Protection Index-600/1000
Absorbed electrical power (HP) (med / max)W600/1000
Thermal power supplied (HP) (med / max)W1920/3200
Maximum distance between unitsm20 (hight max. 10)
Outdoor operating temperature range°C-14 / 43
Refrigerating fluidtipo/gR134a / 1600
Air flowm3/h1300
DIMENSIONS mm
A804
B555
C302
D452
E137

CYLINDER TECHNICAL DATASPLIT 160 (MURAL)
CapacityL160
Dimensions (ø | height)mm530/1141
Gross weightKg.32
Material-Stainless Steel Duplex 2205
Insulation-High density polyurethane (55mm)
Maximum water temperature°C80
Maximum operation pressurebar7
Thermal loss (1)kWh/24h0,94
Protection Index-IPX1
Auxiliary coil powerW1500
Refrigerating connectionspol.1/4” | 3/8”
(1) According to EN12897
PERFORMANCE
Tapping profile-L
COP 2-3,75
COP 3-3,26
Amount of water removed at 40°CL194
Energy efficiency class-A+
Energetic efficiency%135
Annual electricity consumptionkWh/year759
(2) A14/t35, EN16147
(3) EN16147: EN16147: Water heating from 10°C to 54°C (air temperature 14°C)
DIMENSIONS mmSPLIT 160 (MURAL)
A1141
530
C550
D750
E235
F275
G220

 

CYLINDER TECHNICAL DATASPLIT 250 I/IXSPLIT 300 I/IXSPLIT 500 I/IX
CapacityL250 / 245300 / 295455 / 445
Dimensions (ø | height)mm580 / 1540650 / 1400650 / 2020
Gross weightKg.46 / 5150 / 5573 / 95
Material-Stainless Steel AISI444
Insulation-High density polyurethane (55mm)
Corrosion protection-Magnesium anode 1” 1/4 (if applicable)
Maximum water temperature°C80
Maximum operation pressurebar7
Thermal loss (1)kWh/24h1,011,171,81
Coil (ø | length)m0,025 | 100,025 | 100,025 | 24
Coil thermal power (2)kW202054
Protection Index-IPX1
Auxiliary coil powerW150015002200
Refrigerating connectionspol.1/4” | 3/8”1/4” | 3/8”1/4” | 3/8”
(1) According to EN12897
(2) Primary circuit (Te=90°C; Ts=80°C); DHW circuit (Te=10°C; Ts=60°C)
PERFORMANCE
Tapping profile-XLXLXXL
COP 3-3,43,43,5
Amount of water removed at 40°CL323362599
Energy efficiency class-A+A+A+
Energetic efficiency%139143139
Annual electricity consumptionkWh/ano120311701549
(3) EN16147: Water heating from 10°C to 54°C (air temperature 14°C)
DIMENSIONS mmSPLIT 250 I/IXSPLIT 300 I/IXSPLIT 500 I/IX
A99107102
B215236635
C7066361525
D840787782
E102510961093
F134311871770
G147513301937
H154014002020
IØ 580Ø 650Ø 650
J688758758

catalogs

BIM
ENERGIE EST, Lda.
enunidadeexterior_e.rar
ENERGIE EST, Lda.
enaquapurasplit160_e.rar
ENERGIE EST, Lda.
enaquapurasplit_e.rar

Installation manuals
ENERGIE EST, Lda.
enTechnical Manual R15V2 EN

Budget request

We have a multidisciplinary team of professionals capable of finding the best solution for your project.

Budget request
First Name
Last Name
What do you need?
Privacy Policy
PROJETO CO-FINANCIADO
PRR